CMA 11 Microdialysis Probes

£0

Out of stock

SKU: 00146 Category:

Description

NEW CMA 11 PROBE FOR BIG MOLECULES!

Ideal for discrete areas in the CNS due to its greater spatial resolution and reduced size. Causes less tissue damage than other probe types.

  • Small diameter
  • High spatial resolution
  • Causes minimal tissue damage
  • Low internal volume
  • Membrane lengths: 1, 2, 3 or 4 mm
  • Membrane diameter: 0.24 mm (6 kDa), 0.26 mm (55 kDa) or 0.28 mm (500 kDa or 2 MDa)
  • Available metal free or β-irradiated

Item Listing

Item# Description Price Quantity
CMA8309581 CMA 11 6 kDa Microdialysis Probe, 1 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8309582 CMA 11 6 kDa Microdialysis Probe, 2 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8309583 CMA 11 6 kDa Microdialysis Probe, 3 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8309584 CMA 11 6 kDa Microdialysis Probe, 4 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8011081 CMA 11 6 kDa Metal Free Microdialysis Probe, 1 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8011082 CMA 11 6 kDa Metal Free Microdialysis Probe, 2 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8011083 CMA 11 6 kDa Metal Free Microdialysis Probe, 3 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8011084 CMA 11 6 kDa Metal Free Microdialysis Probe, 4 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8011001 CMA 11 6 kDa β-Irradiated Microdialysis Probe, 1 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8011002 CMA 11 6 kDa β-Irradiated Microdialysis Probe, 2 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8011003 CMA 11 6 kDa β-Irradiated Microdialysis Probe, 3 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8011004 CMA 11 6 kDa β-Irradiated Microdialysis Probe, 4 mm membrane length (pkg. of 3) Request for Quote Request for Quote
CMA8012511 CMA 11 55 kDa Microdialysis Probe, 1 mm membrane length, pkg. of 3 Request for Quote Request for Quote
CMA8012512 CMA 11 55 kDa Microdialysis Probe, 2 mm membrane length, pkg. of 3 Request for Quote Request for Quote
CMA8012513 CMA 11 55 kDa Microdialysis Probe, 3 mm membrane length, pkg. of 3 Request for Quote Request for Quote
CMA8012514 CMA 11 55 kDa Microdialysis Probe, 4 mm membrane length, pkg. of 3 Request for Quote Request for Quote
CMA8012521 CMA 11 500 kDa Microdialysis Probe, 1 mm membrane length, pkg. of 3 Request for Quote Request for Quote

Full Description

NEW CMA 11 PROBE FOR BIG MOLECULES!

The CMA 11 Microdialysis Probe is ideal for discrete areas in the CNS due to its greater spatial resolution and reduced size. It causes less tissue damage than other probe types due to its small diameter.

The probe has a cuprophane membrane with an outside diameter of 0.24 mm. The outer steel shaft diameter is 0.38 mm. The inner cannula is constructed of fused silica coated with polyimid. The inlet/outlet capillaries are mounted in a white plastic body matched to the size of a corresponding guide cannula.

New CMA 11 microdialysis probes are now available with a 55 kDa cut-off and 0.26 mm outer diameter (more details in the Specifications section).

New CMA 11 microdialysis probes for big molecules are also now available with 500 kDa and 2 MDa cut-off, 0.28 mm outer diameter and 14 mm shaft length (more details in the Specifications section).

Once implanted, the probe sits tightly in the guide cannula´s capsule without the need for screwing or cementing. FEP tubing is connected to the probe using tubing adaptors.

Standard part numbers are available for metal free or β-irradiated CMA 11 6kDa probes.

For metal free or β-irradiated CMA 11 55 kDa, 500kDa and 2MDa probes, please make your request using our Custom Probe Form and send it to our Technical Support Team. We will contact you promptly.

CMA 11 Microdialysis Probes are guaranteed for single use.

Specifications

Specifications CMA8309581 CMA8309582 CMA8309583 CMA8309584 CMA8011081 CMA8011082 CMA8011083 CMA8011084 CMA8011001 CMA8011002 CMA8011003 CMA8011004 CMA8012511 CMA8012512 CMA8012513 CMA8012514 CMA8012521
Membrane Length 1 mm 2 mm 3 mm 4 mm 1 mm 2 mm 3 mm 4 mm 1 mm 2 mm 3 mm 4 mm 1 mm 2 mm 3 mm 4 mm 1 mm
Membrane O D 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.26 mm 0.26 mm 0.26 mm 0.26 mm 0.28 mm
Membrane Material Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Polyestersulfone (PES) Polyestersulfone (PES) Polyestersulfone (PES) Polyestersulfone (PES) Polyestersulfone (PES)
Molecular Weight Cut-off 6 kD 6 kD 6 kD 6 kD 6 kD 6 kD 6 kD 6 kD 6 kD 6 kD 6 kD 6 kD 55 kD 55 kD 55 kD 55 kD 500 kD
Shaft Diameter 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm
Shaft Length Metric 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm 14 mm
Inlet Volume negligible negligible negligible negligible negligible negligible negligible negligible negligible negligible negligible negligible 0.1 µL 0.1 µL 0.1 µL 0.1 µL 0.1 µL
Outlet Volume 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL 1 µL
Model Standard Standard Standard Standard Metal Free Metal Free Metal Free Metal Free β-Irradiated β-Irradiated β-Irradiated β-Irradiated Standard Standard Standard Standard Standard

Journal Articles

Dahlberg D, Mariussen E, Goverud IL, Tønjum T, Mæhlen J, Antal EA, Hassel B. (2015 ) Staphylococcal α-hemolysin is neurotoxic and causes lysis of brain cells in vivo and in vitro Neurotoxicology.

Garrity AG, Botta S, Lazar SB, Swor E, Vanini G, Baghdoyan HA, Lydic R. (2015 ) Dexmedetomidine-induced sedation does not mimic the neurobehavioral phenotypes of sleep in sprague dawley rat. Sleep.

Selected Recent Publications

Devroye, C. et al., 2017. Opposite control of mesocortical and mesoaccumbal dopamine pathways by serotonin2B receptor blockade: Involvement of medial prefrontal cortex serotonin1A receptors. Neuropharmacology, 119, pp.91–99.

Zhang, C. et al., 2017. Reduced GABAergic transmission in the ventrobasal thalamus contributes to thermal hyperalgesia in chronic inflammatory pain. Scientific Reports, 7. Available at: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5288727/.

Kim, M. et al., 2017. Changes in dopamine, serotonin and their metabolites in brain microdialysates from rats following exposure to new psychoactive drugs. Forensic Toxicology, 35(1), pp.66–76.

Jin, W. et al., 2017. Acupuncture reduces relapse to cocaine-seeking behavior via activation of GABA neurons in the ventral tegmental area. Addiction Biology, p.n/a-n/a.

Dupuis, A. et al., 2017. Increasing spinal 5-HT2A receptor responsiveness mediates anti-allodynic effect and potentiates fluoxetine efficacy in neuropathic rats. Evidence for GABA release. Pharmacological Research, 118, pp.93–103.

Shadgan, B. et al., 2017. Optical monitoring of spinal cord hemodynamics, a feasibility study. In p. 100720T– 100720T–9. Available at: http://dx.doi.org/10.1117/12.2248776.

Cao, F., Zhang, L. & Tian, Y., 2016. A novel N-doped carbon nanotube fiber for selective and reliable electrochemical determination of ascorbic acid in rat brain microdialysates. Journal of Electroanalytical Chemistry, 781, pp.278–283.

Herrera, A. et al., 2016. Aminochrome induces dopaminergic neuronal dysfunction: a new animal model for Parkinson’s disease. Cellular and Molecular Life Sciences, 73(18), pp.3583–3597.

Kim, M. et al., 2016. Silica stationary phase-based on-line sample enrichment coupled with LC-MS/MS for the quantification of dopamine, serotonin and their metabolites in rat brain microdialysates. Analytica Chimica Acta, 923, pp.55–65.

Schober, A. et al., 2016. Microdialysis Assessment of Cerebral Perfusion during Cardiac Arrest, Extracorporeal Life Support and Cardiopulmonary Resuscitation in Rats– A Pilot Trial. PLOS ONE, 11(5), p.e0155303.

Visit our Publications page for a complete listing of CMA 11 publications.