The CMA 402 Syringe Pump is a compact, flexible, dual syringe pump designed for low pulse-free flow rates suitable for microdialysis experiments and other low flow experiments. Start/Stop and flow rate can be set individually for each syringe.

The pump is precalibrated for 1, 2.5 or 5 mL syringes with flow rates between 0.1 µL/min and 20 µL/min. The flow rates are shown on the LED displays. The CMA 402 Microdialysis Pump is even more flexible when controlled by a computer through the RS-232 interface. For instance, a preset volume can easily be set. A flush feature fills the system at a flow rate of 25 µL/min. The CMA 402 is available in two different versions, one of which includes accessories such as vial holders and probe clips, allowing easier handling of the microdialysis probe.

Item#

Description

CMA8003100

CMA 402 Microdialysis Syringe Pump with Accessory Kit

CMA8003110

CMA 402 Microdialysis Syringe Pump

CMA8002773

USB Cable, Type A-B

The CMA 402 Syringe Pump is a compact, flexible, dual syringe pump designed for low pulse-free flow rates suitable for microdialysis experiments and other low flow experiments.

  • Dual syringes independently controlled
  • Flow rates from 0.1- 20 µL/min
  • Independent flow directions to infuse or withdraw

Start/Stop and flow rate can be set individually for each syringe. The pump is precalibrated for 1, 2.5 or 5 mL syringes with flow rates between 0.1 µL/min and 20 µL/min. The flow rates are shown on the LED displays. The CMA 402 Microdialysis Pump is even more flexible when controlled by a computer through the RS-232 interface. For instance, a preset volume can easily be set. A flush feature fills the system at a flow rate of 25 µL/min. The CMA 402 is available in two different versions, one of which includes accessories such as vial holders and probe clips, allowing easier handling of the microdialysis probe.

Specifications CMA8003100 CMA8003110
Accuracy ±1.5% ±1.5%
Calibration Precalibrated Precalibrated
Certifications CE CE
Computer connection RS232 and USB RS232 and USB
Dimensions 207 x 135 x 48 mm (W x D x H) 207 x 135 x 48 mm (W x D x H)
Display 2-digit LED display showing flow rate or syringe size 2-digit LED display showing flow rate or syringe size
External connections Variable Variable
Fast Feed Approx.20 µL/min (with 1 mL syringe) Approx.20 µL/min (with 1 mL syringe)
Flow rate range 0.1 µL/min – 20 µL/min 0.1 µL/min – 20 µL/min
Motor High resolution step motor system High resolution step motor system
Motor Drive Control
Number of syringes 2, Indep. Control 2, Indep. Control
Piston carriage speed 2.4 µm/min-1.2 mm/min 2.4 µm/min-1.2 mm/min
Power consumption 10 W max 10 W max
Speed variation ±1.5% ±1.5%
Syringe sizes 1, 2.5 and 5 mL, piston stroke 60 mm 1, 2.5 and 5 mL, piston stroke 60 mm
Voltage 100-240 VAC 50-60 Hz, output 12 VDC (adapter included) 100-240 VAC 50-60 Hz, output 12 VDC (adapter included)
Weight approx. 1.4 kg approx. 1.4 kg
Working temperature 10-35°C 10-35°C

Journal Articles

Deding Liu, Shuogui Xu, Heping Xiao, Zhuo Wang, Ningfang Mao, Jia Zhou, Rui Liu & Yi Huang (2014) Quantitative determination of unbound levofloxacin by simultaneous microdialysis in rat pancreas after intravenous and oral doses Journal of Pharmacy and Pharmacology

Lisa Amanda Holm Rottbøll, Kerstin Skovgaard, Kristiane Barington, Henrik Elvang Jensen & Christian Friis (2015 ) Intrabronchial Microdialysis: Effects of Probe Localization on Tissue Trauma and Drug Penetration into the Pulmonary Epithelial Lining Fluid Basic & Clinical Pharmacology & Toxicology

Teayoun Kim, John F. Moore, Jon D Sharer, Kevin Yang, Philip A Wood & Qinglin Yang (2014 ) Carnitine Palmitoyltransferase 1b Deficient Mice Develop Severe Insulin Resistance After Prolonged High Fat Feeding Journal of Diabetes & Metabolism

Jingjing Wei, Limei Yao, Lei Yang, Wei Zhao, Si Shia, Qingyan Cai, Dingsheng Chen, Weirong Li & Qi Wang (2015 ) Alteration of glutamate/GABA balance during acute alcohol intoxication in rats: Effect of Xingnaojing injection Journal of Ethnopharmacology

Yanping Cun, Lin Tang, Jie Yan, Chao He, Yang Li, Zhian Hu & Jianxia Xia (2014 ) Orexin A attenuates the sleep-promoting effect of adenosine in the lateral hypothalamus of rats Neuroscience Bulletin