The PHD ULTRA™ Syringe Pump Modules are infusion/ withdrawal pumps. They are available in three configurations: standard, push/pull and high force. These modules include a footswitch input, USB, RS-232, RS-485 and I/O connectors. They can be controlled via PC. You can also start and stop a pump using the 15-pin user I/O connector.

The PHD ULTRA™ is the solution for your most demanding fluidics applications. This pump represents the latest technology in syringe pumps and was developed utilizing the feedback of the world’s largest populations of syringe pump users. This syringe pump platform has superior mechanical drive mechanism and syringe holding mechanics to achieve the highest performance of any syringe pump.

Specifications 70-3506 70-3508 70-3510 70-3514
Accuracy ±0.25% ±0.25% ±0.35% ±0.5%
Classification Class I Class I Class I Class I
Dimensions Control Box LxDxH in cm 11.75 x 5.5 x 6.5 (29.8 x 14 x 16.75) 11.75 x 5.5 x 6.5 (29.8 x 14 x 16.75) 11.75 x 5.5 x 6.5 (29.8 x 14 x 16.75) 11.75 x 5.5 x 6.5 (29.8 x 14 x 16.75)
Drive Motor 0.9° Stepper Motor 0.9° Stepper Motor 1.8° Stepper Motor 1.8° Stepper Motor
Environmental Humidity 20% to 80% RH, non condensing 20% to 80% RH, non condensing 20% to 80% RH, non condensing 20% to 80% RH, non condensing
Environmental Operating Temperature English 40°F to 104°F* 40°F to 104°F* 40°F to 104°F* 40°F to 104°F*
Environmental Operating Temperature Metric 4°C to 40°C* 4°C to 40°C* 4°C to 40°C* 4°C to 40°C*
Environmental Storage Temperatue English 14°F to 158°F 14°F to 158°F 14°F to 158°F 14°F to 158°F
Environmental Storage Temperatue Metric -10°C to 70°C -10°C to 70°C -10°C to 70°C -10°C to 70°C
Flow Rate Maximum 216 ml/min using 140 ml syringe 216 ml/min using 140 ml syringe 216 ml/min using 140 ml syringe 144.08 ml/min using 200 ml syringe
Flow Rate Minimum 1.56 pl/min using 0.5 µl syringe 1.56 pl/min using 0.5 µl syringe 1.56 pl/min using 0.5 µl syringe 50.7 nl/min using 20 ml syringe
I/O & TTL Connectors 15 pin D-Sub Connector 15 pin D-Sub Connector 15 pin D-Sub Connector 15 pin D-Sub Connector
Input Power 50 W, 0.5 A fuse 50 W, 0.5 A fuse 50 W, 0.5 A fuse 50 W, 0.5 A fuse
Installation Category II II II II
Max Linear Force 75 lbs @ 100% Force Selection 75 lbs @ 100% Force Selection 200 lbs @ 100% Force Selection 1000 lbs @ 100% Force Selection
Mode of Operation Continuous Continuous Continuous Continuous
Motor Drive Control Microprocessor with 1/16 microstepping Microprocessor with 1/16 microstepping Microprocessor with 1/16 microstepping Microprocessor with 1/16 microstepping
Net Weight English 10 lb 11.2 lb 11.7 lb 10 lb
Net Weight Metric 4.5 kg 5.1 kg 5.3 kg 4.5 kg
No of Syringes 2 4 1 4
Non Volatile Memory Storage of all settings Storage of all settings Storage of all settings Storage of all settings
Number of Microsteps per one rev of Lead Screw 12,800 12,800 6,400 12,800
Pollution Degree 1 1 1 1
Pump Configuration Standard Standard Standard Standard
Pump Function Infuse/Withdraw Push/Pull Infuse/Withdraw Infuse/Withdraw
Pusher Travel Rate Maximum 190.8 mm/min 190.8 mm/min 190.8 mm/min 91.637 mm/min
Pusher Travel Rate Minimum 0.18 µm/min 0.18 µm/min 0.36 µm/min 0.18 µm/min
Regulatory Certifications CE, UL, CSA, CB Scheme, EU RoHS CE, UL, CSA, CB Scheme, EU RoHS CE, UL, CSA, CB Scheme, EU RoHS CE, UL, CSA, CB Scheme, EU RoHS
Step Rate Maximum 26 µsec/µstep 26 µsec/µstep 26 µsec/µstep 52 µsec/µstep
Step Rate Minimum 27.5 sec/µstep 27.5 sec/µstep 27.5 sec/µstep 27.5 sec/µstep
Syringe Rack Type Standard Rack Standard Rack Standard Rack Standard Rack
Syringe Size Maximum 140 ml 140 ml 140 ml 200 ml
Syringe Size Minimum 0.5 µl 0.5 µl 0.5 µl 20 ml
USB Connectors Type B Type B Type B Type B
Voltage Range 100-240 VAC, 50/60 Hz 100-240 VAC, 50/60 Hz 100-240 VAC, 50/60 Hz 100-240 VAC, 50/60 Hz