The NanoCool™ Injector is a single syringe infusion/withdrawal programmable syringe pump with a flow rate range of 367.4 pl/min to 1.906 ml/min with 11 lbs of adjustable force across the entire flow rate range. It can accommodate syringes from 50 µl to 500 µl.

When injecting stem cells viability of cells can be a major issue. The injection system and sample vortex holder are held at 18°C. The cell delivery is totally integrated in it operation through the NanoCool’s microprocessor system: power, temperature, injection volumes and flow ramping are all controlled by the NanoCool’s program. Keeping the cells at 18°C instead of 37°C reduces O2consumption by an average of 76%.

The NanoCool™ Injector is very easy to use with an LCD color touch screen and icon interface. This pump allows you to create, save and run simple to complex Methods without a PC. The Method profiles available on this pump are Constant Rate, Ramp, Stepped, Bolus, Concentration, Gradient (binary or ternary), Pulse and Autofill. Delays can be set using the real and relative time clocks.

Full Description

The NanoCool™ Injector is a single syringe infusion/withdrawal programmable syringe pump with a flow rate range of 367.4 pl/min to 1.906 ml/min with 11 lbs of adjustable force across the entire flow rate range. It can accomodate syringes from 50 µl to 500 µl.

Features:

  • 18°C for optimal cell viability on any delivery syringe and eppendorf
  • 20% Increase in Survivability, 76% Lower O2 Consumption Rate at 18°C vs. 37°C
  • Light weight makes it ideal for hand-held or stereotaxic injection
  • Flow ramping to reduce injection site blowback
  • Programmed methods for automatic recall of entire cell delivery system. Up to 100 methods stored for recall
  • 2-year warranty
  • High accuracy delivery between 367.4 pl/min to 1.906 ml/min
  • Preprogrammed bolus injection mode, just specify injection size and time of dispense
  • Footswitch activation keeps hands free

Applications:

  • Cellular injections
  • Drug Delivery
  • Microinjections
  • Hand-held automated delivery
  • Stereotaxic Injections
  • Feeding cells
  • Regenerative Medicine

When injecting stem cells viability of cells can be a major issue. The injection system and sample vortex holder are held at 18°C. The cell delivery is totally integrated in it operation through the NanoCool’s microprocessor system: power, temperature, injection volumes and flow ramping are all controlled by the NanoCool’s program. Keeping the cells at 18°C instead of 37°C reduces O2 consumption by an average of 76%.

The NanoCool™ Injector is very easy to use with an LCD color touch screen and icon interface. This pump allows you to create, save and run simple to complex Methods without a PC. The Method profiles available on this pump are Constant Rate, Ramp, Stepped, Bolus, Concentration, Gradient (binary or ternary), Pulse and Autofill. Delays can be set using the real and relative time clocks.

The Message Area of the touch screen is used to display helpful instructions for the currently displayed screen. It is also used to display error or warning messages to indicate problem conditions in a Method or error conditions during pump operation. The Run Screen shows all of the pump parameters on one screen for easy review.

The software is organized into three main navigational branches, the quick start Methods, user-defined Methods, and system settings. You can control operations directly through the touch screen or remotely from an independent computer or device via the external I/O interface.

The NanoCool™ Injector has a footswitch input, RS-232 and USB serial ports for computer control, RS-485 ports for daisy chaining pumps and Digital I/O for external control via an independent computer or device. There is also an option for daisy chaining pumps through the RS-232 (RJ-11) ports. This option must be ordered at the time the pump is ordered.

This pump consists of a control unit, an injection unit, a 6 foot cable to connect the two units and a footswitch

Specifications 88-1050
Accuracy ±0.5%
Classification Class I
Dimensions Control Box LxDxH in cm 12 x 8.5 x 4.38 (30.5 x 21.6 x 11.1)
Dimensions Mechanism LxDxH in cm 2.5 x 2.0 x 7.5 (6.35 x 5.08 x 19.05)
Display 4.3″ WQVGA TFT Color Display with Touchpad
Drive Motor 1.8° Stepper Motor
Environmental Humidity 20% to 80% RH, non condensing
Environmental Operating Temperature English 40°F to 104°F
Environmental Operating Temperature Metric 4°C to 40°C
Environmental Storage Temperatue English 14°F to 158°F
Environmental Storage Temperatue Metric -10°C to 70°C
Flow Rate Maximum 367.4 pl/min using 50 µl syringe
Flow Rate Minimum 1.906 ml/min using 500 µl syringe
I O TTL Connectors 15 pin D-Sub Connector
Input Power 75 W, 0.5 A fuse
Installation Category II
Max Linear Force 11 lbs @ 100% Force Selection
Mode of Operation Continuous
Motor Drive Control Microprocessor with 1/16 microstepping
Net Weight Control Box English 4.55 lb
Net Weight Control Box Metric 2.06 kg
Net Weight Remote Mechanism English 1.01 lb
Net Weight Remote Mechanism Metric 0.458 kg
No of Syringes 1
Non Volatile Memory Storage of all settings
Number of Microsteps per one rev of Lead Screw 3,200
Pollution Degree 1
Pump Configuration Remote
Pump Function Infuse/Withdraw, Programmable
Pusher Travel Rate Maximum 228.97 mm/min
Pusher Travel Rate Minimum 0.433 µm/min
RS 232 Connectors 9 pin D-Sub Connector
Regulatory Certifications CE, ETL (UL, CSA), WEE, EU RoHS & CB Scheme
Step Rate Maximum 52 µsec/µstep
Step Rate Minimum 27.5 sec/µstep
Syringe Rack Type Standard Rack
Syringe Size Maximum 500 µl
Syringe Size Minimum 50 µl
USB Connectors Type B