UHK-TA Ultimate Human Physiology Teaching Kit

£0

SKU: UHK-TA Category:

Description

Ultimate Human Physiology Teaching Kit

The UHK-TA Ultimate Human Physiology Teaching Kit includes all of the necessary hardware and components, LabScribe software and expertly written courseware to teach 59 experiments and more than 175 exercises in cardiovascular, respiratory, and neuromuscular physiology.

Courseware
These Lab Exercises can be performed with the UHK-TA kit.

Human Circulation

  • HC-01: Blood Pressure, Peripheral Circulation and Body Position
  • HC-02: Blood Pressure, Peripheral Circulation and Imposed Conditions
  • HC-03: Pulse Wave Velocity
  • HC-04: Pulse Contour Analysis
  • HC-05: Body Position, Exercise and Cardiac Output
  • HC-06C: Effects of Temperature on Peripheral Oxygen Saturation Levels

HumanExercise

  • HE-01: Metabolism and Thermal Response to Exercise
  • HE-02: Recovery from Exercise
  • HE-03C: Exercise, Blood Pressure and Oxygen Saturation Levels

Human Heart

  • HH-01: Electrocardiogram (ECG) and Peripheral Circulation
  • HH-02: ECG and Heart Sounds with Stethoscope
  • HH-03: Exercise, the ECG and Peripheral Circulation
  • HH-04: Six Lead ECG
  • HH-05A: The Diving Reflex
  • HH-05B: The Diving Reflex with Respiration rate
  • HH-06: Heart Rate Variability
  • HH-08: Auscultation
  • HH-12: Pulse and Heart Rate Variability (HRV)

Human Muscle

  • HM-01: Grip Strength and the Electromyogram
  • HM-02: Electromyogram Activity in Antagonistic Muscles
  • HM-03: Oculomotor Muscle Activity
  • HM-04: Stimulus Response, Work, Summation and Tetanus in Human Muscles
  • HM-08: Electromyogram (EMG) Activity while Arm Wrestling
  • HM-09: Kinesiology and Electromyogram (EMG) Activity in Targeted Muscles
  • HM-10: The Electrogastrogram (EGG) and Growling Stomach
  • HM-11: Electromyogram (EMG) for Paired Arm Wrestling

Human Nerve

  • HN-01: Auditory and Visual Reflexes
  • HN-02A: Stretch Receptors and Reflexes with Reflex Hammer
  • HN-02B: Stretch Receptors and Reflexes with Plethysmograph
  • HN-03: Human Nerve Conduction Velocity
  • HN-06: Hoffman Reflex using the Soleus Muscle
  • HN-07: Median Nerve Conduction Velocity
  • HN-08: Game Show Physiology

Human PsychoPhysiology

  • HP-02: Galvanic Skin Response and Emotion
  • HP-03: Galvanic Skin Response and Deception, Coginitive Compliance and Vigilance
  • HP-04: Skin Temperature, Stress, Calming and Embarrassment
  • HP-05A: Heart Rate and Blood Pressure
  • HP-05B: Personality and Vagal Tone
  • HP-05C: Vigilance and Reaction Time
  • HP-06: Cynicism-Hostility and the Hot Reactor
  • HP-07: The Stroop Effect
  • HP-08: The Galvanic Skin Response (GSR) and Investigation into Cheating
  • HP-09: Facial Expression Electromyograms (EMG) and Emotion
  • HP-10: Visual Evoked Potentials (VEP)
  • HP-11: Multisensory Reaction Times
  • HP-12: Rubber Hand Illusion
  • HP-13: The Gaze Cue Paradigm
  • HP-14: Hypothesis-driven Biofeedback Lab/Research Study
  • HP-16: Eriksen Flanker Test

Human Spirometry

  • HS-01: Breathing Parameters at Rest and After Exercise
  • HS-02: Breathing and Gravity
  • HS-03: Factors that Affect Breathing Patterns
  • HS-04: Lung Volumes and Heart Rate
  • HS-05: Breathing Techniques and Heart Rate
  • HS-06C :Ventilation and Oxygen Saturation Levels – Part 1
  • HS-07C: Ventilation and Oxygen Saturation Levels – Part 2
  • HS-08: Restrictive and Obstructive Airway Diseases

Tutorial

  • TT-01: Tutorial with ECG
  • TT-02: Tutorial with pulse

The kit includes:

  • IX-TA-220: iWorx TA Recorder with built-in Spirometer, Heart Sounds Sensor, Grip Force/Blood Pressure Sensor, Temperature Sensor, O2 Electrode Input, two iWire Digital Interfaces, High and Low Voltage Stimulators.
  • LabScribe Software with site license and free updates.
  • iWire-B3G Isolated ECG and EMG iWire Recording Module.
  • A-BNC-HP: HeadPhone.
  • A-FH-300: Spirometry – Re-useable Flow Head 300L.
  • BP-220: Blood Pressure Cuff and valve .
  • C-HVS-SL2: Stimulator Cable – Set 2 (Red and Black) Safety to Snap-Lead.
  • C-ISO-GSR: GSR Finger Electrodes (Set of Two) for iWire-B3G Recording Module.
  • C-ISO-SC7: EEG Silver-SilverChloride Cup electrodes.
  • C-ISO-SL7: Recording Leads – 7 Safety Pin to Snap Connectors.
  • C-USB: USB Cable.
  • EM-220: Event Marker with Phono Connector
  • FT-220: Hand Dynamometer with A-BT-220 Tubing .
  • GN-100: Single-Axis Goniometer.
  • HSM-220: Stethoscope and tubing .
  • PO2-CMS50D: USB Pulse Oximeter (Includes finger sensor) .
  • PRH-200: Patellar Reflex Hammer.
  • PT-104: Pulse Plethysmograph (piezo crystal).
  • RM-204: Respiration Monitor (piezo crystal)
  • SMT-220: Striated Muscle Transducer
  • TM-220: Temperature Probe.
  • A-GC-7165: Disposable Adult Electrodes – 150 per package.
  • A-GSR-GEL: Skin Resistance/Conductance Electrode Paste.
  • A-KB-TA: Kit Box for HK-TA.
  • A-SRK-1: Student Respiration Kit.
  • A-ST-300-TA: Spirometer Silicon Tubing with red and white luer fittings .
  • A-UP12-DC-25-1.5A: Univ. 12VDC Power Supply for IX-TA.

Optional Addon Kits:

  • Animal Physiology Transducer Set
  • Neurobiology Teaching Set
  • Human Exercise Physiology Teaching Set
  • Invertebrate Transducer Set
  • Extracellular Teaching Set
  • General Biology Teaching Set
  • List of all transducers compatible with the IX-TA-220