Ventilation Options for IPL-1

£0

SKU: 00066 Category:

Description

For a functional IPL-2 unit the core system requires a suitable ventilation system.For only positive ventilation a mouse ventilator can be used. If positive and sub-atmospheric pressure ventilation is required, the Ventilation Control Module must be purchased.

Full Description

For a functional unit the core system requires a suitable ventilation system. For only positive ventilation a mouse ventilator can be used. If positive and sub-atmospheric pressure ventilation is required, the Ventilation Control Module must be purchased.

Positive and Sub-Atmospheric (Negative) PressureVentilation with Ventilation Control Module (VCM)

  • Used to control the ventilation of the isolated lung preparation. Allows for the physiological negative pressure ventilation of the lung and positive ventilation during preparation.
  • 30 to 100 breaths per minute.
  • I:E ratio can be set between 10 and 90% in 10% steps.
  • End-inspiratory, end-expiratory, sigh, positive and negative pressures can be individually set.
  • The TCM Timer Counter Module allows periodic sigh (hyperinflation) breaths to minimize edema formation.
  • An adapter to supply the trachea with a gas mixture different than roomair during negative ventilation can be added.
Negative PressureVentilation Control Optionwith Pump for IPL-1 & 2 (73-4279) includes:
(Utilizes 6 slot units)
Negative PressureVentilation Control Optionwith Pressure Regulator forIPL-1 (73-4293) includes:
(Utilizes 6 slot units)
Item # Product Name Item # Product Name
73-1741 PLUGSYS Ventilation Control Module with Integral Pump (VCM-P) 73-2795 PLUGSYS Ventilation ControlModule with Regulator(VCM-R)*
73-1750 PLUGSYS Time CounterModule (TCM) 73-1750 PLUGSYS Time CounterModule (TCM)
N/A See above 73-2789 Pressure-Free Gas Supply Adapter for Alternative Gas Supply**

* Negative pressure ventilation with a pressure regulator (73-4293) built into the VCM-R requires a pressurized gas supply from a tank or house air in the range of 2 to 8 barS (29 to 116 PSI).

** The Pressure-Free Gas Supply Adapter (73-2789) is only for use during sub-atmospheric pressure ventilation with either the VCM-P or VCM-Rand is used to supply alternative gas mixtures to the lungs.

Positive Pressure Ventilation Only

If only positive pressure ventilation will be used, choose an option below.

  • Ventilation rate from 60 to 400 breaths per minute.
  • Stroke volume 30 to 350 μl, simple adjustment while running.
  • Compact size allows positioning close to system for minimal system volume.
Positive Pressure Ventilation Option, 230 V (73-4305) includes: Positive Pressure Ventilation Option,115 V (73-4306) includes:
Item # Product Name Item # Product Name
73-0044 Mouse Ventilator MiniVent Type 845, 230 V 73-0043 Mouse Ventilator MiniVent Type 845, 115 V
73-2792 PLUGSYS Time Counter Module (TCM) 73-2792 PLUGSYS Time Counter Module (TCM)